W1000 Inverter for Water Pump Applications

MOQ : 1

Price : $200 - $2500

Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram

Delivery Time : 3-5Workday

Model Number : W1000

Place of Origin : Japan

Product Name : Frequency Converte Inverter

Voltage Classes : 3-Phase 380V-480V

Rated Power : 0.75kW - 355kW

Warranty : Original Factory Warranty

Pakage : Original Pakage

Shipping Term : International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/ Sea Freight / Air Freight / International Special Line

Contact Now

W1000 Inverter for Water Pump Applications
Advanced inverter solution designed specifically for water pump applications, featuring energy-saving control technology for efficient operation with both induction motors (IM) and synchronous motors (SM). The silent control function automatically reduces voltage during low-speed or light-load operation, delivering low-noise and energy-efficient performance.
Core Features
Energy Efficiency & Dual-Motor Compatibility
  • Dedicated Energy-Saving Control Technology for both Induction Motors (IM) and Synchronous Motors (SM)
  • Automatic voltage optimization under low-speed or light-load conditions
  • 10%-30% improved energy efficiency compared to standard inverters
  • Synchronous motor driving eliminates rotor copper loss, lowers bearing temperature, and extends motor lifespan
Multi-Pump Intelligent Control
  • Fixed Variable-Speed Pump Mode: 1 variable-speed pump + up to 3 constant-speed pumps (expandable to 11 with optional DO-A3 card)
  • Rotation Switch Mode 1: Cycle variable-speed control for up to 5 pumps (requires DO-A3 card)
  • Rotation Switch Mode 2: Cycle variable-speed control for up to 3 pumps (expandable to 11 with optional DO-A3 card)
Low-Noise Operation & Environmental Adaptability
  • Swing PWM switching technology minimizes electromagnetic interference and operating noise
  • Moisture and dust resistance design compliant with RoHS environmental directives
  • Suitable for harsh environments including outdoor pump rooms and basements
High-Precision Control & Stable Performance
  • High-precision torque limitation (±5% error) under vector control
  • High-speed response above 50Hz with PG feedback control
  • Adjustable acceleration/deceleration time (0.1-3600s)
  • S-curve characteristic switching to prevent water hammer and pipeline vibration
Safety & Long-Life Design
  • Compliant with EN954-1 Cat.3 and IEC/EN61508 SIL2 safety standards
  • EDM (External Device Monitoring) function for real-time safety circuit monitoring
  • 10-year inverter design life with built-in wear part life diagnosis
  • KEB (Kinetic Energy Backup) function for rapid motor shutdown during power outages
Easy Maintenance & Expandability
  • Detachable terminal block with parameter backup function
  • Standard RS-422/485 communication interface
  • Support for PROFIBUS-DP, DeviceNet, CC-Link, and other fieldbuses
  • Compatible with DriveWorksEZ visual programming and DriveWizard Plus debugging tools
Key Technical Specifications
Category Specifications Notes
Input Power 3-Phase 380V-480V ±10%, 50/60Hz Compatible with global mainstream industrial power grids
Rated Output Power 0.75kW - 355kW Models: CIMR-EB4W0002 (0.75kW) to CIMR-EB4W0675 (355kW)
Rated Output Current 2.1A (0.75kW) - 675A (355kW) Refer to factory selection manual for specific values
Output Frequency Range 0.01Hz - 600Hz Meets high-speed pump operation requirements
Control Mode V/F Control, Sensorless Vector Control, Vector Control with PG Torque control accuracy ±5% (with PG vector mode)
Frequency Accuracy Digital: ±0.01%; Analog: ±0.2% Ensures stable constant-pressure water supply
Braking Function Built-in brake transistor, supports over-excitation braking Heavy-duty models require optional brake unit
Protection Functions Overcurrent, Overload, Overvoltage, Undervoltage, Overheating, Phase Loss, Torque Limitation Comprehensive protection for pumps and inverters
Environmental Adaptability Temperature: -10℃~+45℃; Humidity: 20%~90%RH Custom high/low temperature versions available
Protection Class IP20 (standard), optional IP54 High-protection version for outdoor installation
Certifications CE, UL/cUL, RoHS, SIL2 Complies with EU/US market access requirements
Typical Applications
  • Municipal water supply systems and sewage treatment plants
  • Industrial cooling water circulation and central air conditioning systems
  • Secondary water supply for high-rise buildings and community constant-pressure water supply
  • Agricultural irrigation and water conservancy project pump stations
  • Corrosion-resistant pumps in chemical and pharmaceutical industries
Model Information
Model Naming Convention
Model Component Meaning Example
CIMR- Yaskawa Inverter Universal Prefix CIMR-
EB4W Series Identifier (W1000 Water Pump-Specific, 380-480V 3-Phase) EB4W
00XX Capacity Code (Corresponding to Rated Output Power) 0002 (for 0.75kW)
Suffix (Optional) -HT: High-Temperature Version; -IP54: High-Protection Version CIMR-EB4W0018-HT
Core Model Specifications
Model Rated Power Rated Current Motor Type Overload Capacity Protection Class Certifications
CIMR-EB4W0002 0.75kW 2.1A IM/SM 150% 60s IP20/IP54 CE, UL/cUL, RoHS, SIL2
CIMR-EB4W0004 1.5kW 4.1A IM/SM 150% 60s IP20/IP54 CE, UL/cUL, RoHS, SIL2
CIMR-EB4W0005 2.2kW 5.4A IM/SM 150% 60s IP20/IP54 CE, UL/cUL, RoHS, SIL2
CIMR-EB4W0007 3.0kW 6.9A IM/SM 150% 60s IP20/IP54 CE, UL/cUL, RoHS, SIL2
CIMR-EB4W0009 3.7kW 8.8A IM/SM 150% 60s IP20/IP54 CE, UL/cUL, RoHS, SIL2
CIMR-EB4W0011 5.5kW 11.1A IM/SM 150% 60s IP20/IP54 CE, UL/cUL, RoHS, SIL2
CIMR-EB4W0018 7.5kW 17.0A IM/SM 150% 60s IP20/IP54 CE, UL/cUL, RoHS, SIL2
Additional models available up to 355kW - contact for complete specifications
Selection Notes for Overseas Markets
  • Voltage Matching: Compatible with global industrial power grids (380-480V 3-Phase, 50/60Hz)
  • Certification Adaptation: CE for European market, UL/cUL for North America
  • Load Adaptation: Reserve 20% power margin for heavy-load scenarios
  • Accessory Matching: Recommended brake units for high-power models (≥45kW)
Frequently Asked Questions
Q1: Pressure fluctuations during low water demand in European municipal projects?
Adjust Pr.144 (PI Proportional Gain) to 3.0 and Pr.145 (PI Integral Time) to 15.0s. Enable Pr.575 (Sleep/Wake Function) with sleep threshold at 80% of rated pressure. This reduces pressure fluctuation to ±0.1 bar.
Q2: Overheating faults in Southeast Asian sewage treatment plants?
Clean heat sink and fan filter every 2 weeks with compressed air. Install additional axial fan (150m³/h) in electrical cabinet for improved air circulation. Avoid installation near sewage pump to reduce humidity exposure.
Q3: Pressure drop during pump switching in multi-pump systems?
Set Pr.A21 (Multi-Pump Pre-Excitation Time) to 0.5s and Pr.A22 (Pre-Excitation Torque) to 10%. This preloads torque to standby pump before valve opens, reducing switching delay to 0.3 seconds.
Q4: Derating in high-temperature Middle Eastern environments?
Install inverter vertically, add sunshade cover to electrical cabinet, and set Pr.73 (Overload Protection Level) to 120% 60s. For permanent solution, upgrade to -HT high-temperature model (operates up to 55℃).
Q5: Communication issues with Siemens PLC in German chemical plants?
Use optional PROFIBUS-DP/Profinet card (SI-P1). Set Profinet Device Name to match PLC configuration and map pressure data to Process Data Object (PDO). Use shielded CAT5e or higher cable to prevent interference.
Q6: Parameter recovery without damaged terminal block?
Use USB drive with DriveWizard Plus software via front USB port, or use RS-485 cable to copy parameters from another W1000 in same system using Pr.970 (Parameter Copy) function.
Q7: Rust issues in seawater desalination applications?
Upgrade to IP54 high-protection model with corrosion-resistant coating. Temporary solution: apply marine-grade anti-corrosion spray and install dehumidifier in cabinet.
Q8: Overcurrent faults during fire pump startup?
Change control mode to "V/f control" (Pr.79 to 1), increase acceleration time to 5.0s (Pr.71), and enable Pr.250 (Fire Pump Mode). Check for stuck impeller causing high startup load.

Product Tags:

water pump inverter W1000

      

frequency inverter for water pumps

      

W1000 inverter with warranty

      
Buy cheap W1000 Inverter for Water Pump Applications product

W1000 Inverter for Water Pump Applications Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shanghai Fradwell Industrial Automation Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)